Study of Supercapacitor Energy Storage Converter with Unbalanced and Nonlinear Loads

Article Preview

Abstract:

A novel topology structure of supercapacitor energy storage converter (ESC) is presented with two cascaded bidirectional DC/DC converters connected to a bidirectional DC/AC converter. It can promote the energy utilization rate of supercapacitor and improve the ability of powering unbalanced and nonlinear loads. The effect of the midpoint voltage fluctuation of the cascaded connected DC bus capacitors on output voltage is analyzed, followed by the influence mechanism unbalanced and nonlinear loads. The control strategy to restrain the unbalance and zero sequence harmonic is proposed. The theoretical analysis and the proposed method are verified through simulations and experiments on a 100kVA supercapacitor ESC prototype.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1561-1568

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Xie Shaojun, Yan Yangguang. Studies of Switching-Nodes Perset 3-Phase 4-Line SPWM Inverter. Acta Aeronautica et Astronautica Sinica, 1992 12 (13) B618-B624.

Google Scholar

[2] Chen Ling, Zhang Xing, Yang Shuying, Xie Zhen. Study on the three-phase four-leg inverter with unbalanced loads. Journal of HeFei University of Technology, 2009 4 (32) 486-490.

Google Scholar

[3] Ruan Xinbo, Yan Yangguang. The Control Strategy for Three-Phase Inverter with Four Bridge Legs. Transactions of China Electrotechnical Society, 2000 1 (15) 61-64.

Google Scholar

[4] Hu Wenhua, Ma Weiming, Liu Chunxi. Resrarch on a Novel Control Strategy for Unbalanced Load. Electric Drive, 2009 10 (39) 3-7.

Google Scholar

[5] Kyung-Hwan Kim, Nam-Joo Park, Dong-Seok Hyun. Advanced Synchronous Reference Frame Controller for three-Phase UPS Powering Unbalanced and Nonlinear Loads. Power Electronics Specialists Conference, 2005. PESC '05. IEEE 36th, 1699-1704.

DOI: 10.1109/pesc.2005.1581859

Google Scholar

[6] Bai Dan, Cai Zhikai, Peng Li, Kang Yong, Chen Jian. Study on The Unbalanced Load of A Three-Phase Inverter. Automation of Electric Power Systems, 2004 9 (28) 53-57.

DOI: 10.1109/apec.2004.1295799

Google Scholar

[7] L. Rossetto, L. Malesani, P. Tenti, S. Buso, A. Pollmann, Fully Digital Control of A Three- phase UPS by VECON Integrated Controller, IEEE Industry Applications Conference, 1995, 3: 2663-2669.

DOI: 10.1109/ias.1995.530642

Google Scholar