Abstract:

This study aims to analyze the functional contact pressure induced by Removable Partial Denture (RPD) by using a 3D finite element (FE) model constructed based on patient specific CT scans. This model was validated against the in vivo test results. The outcomes demonstrate that the finite element simulation has the capability of quantifying localized stress distribution in a complicated denture-mucosa contact problem, with a reasonable matching to clinical measurements of occlusal force and pressure distribution. The methodology is of considerable clinical implication to improve the long term outcomes of the denture treatment.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

322-326

Citation:

Online since:

May 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Carlsson, G.E., Responses of jawbone to pressure. Gerodontology, 2004. 21(2): pp.65-70.

DOI: 10.1111/j.1741-2358.2004.00005.x

Google Scholar

[2] Ahmad, R., et al., Three dimensional quantification of mandibular bone remodeling using standard tessellation language registration based superimposition. Clin Oral Implants Res, 2013. 24(11): pp.1273-1279.

DOI: 10.1111/j.1600-0501.2012.02566.x

Google Scholar

[3] Kanbara, R., et al., Three-dimensional finite element stress analysis: the technique and methodology of non-linear property simulation and soft tissue loading behavior for different partial denture designs. Dent Mater J, 2012. 31(2): pp.297-308.

DOI: 10.4012/dmj.2011-165

Google Scholar

[4] Wang, H.Y., et al., Effects of rigid and nonrigid extracoronal attachments on supporting tissues in extension base partial removable dental prostheses: a nonlinear finite element study. J Prosthet Dent, 2011. 105(5): pp.338-46.

DOI: 10.1016/s0022-3913(11)60066-8

Google Scholar

[5] Verri, F.R., et al., Evaluation of bone insertion level of support teeth in class I mandibular removable partial denture associated with an osseointegrated implant: a study using finite element analysis. Implant Dent, 2011. 20(3): pp.192-201.

DOI: 10.1097/id.0b013e3182166927

Google Scholar

[6] Kubo, K., et al., Development of in vivo measuring system of the pressure distribution under the denture base of removable partial denture. J Prosthodont Res, 2009. 53(1): pp.15-21.

DOI: 10.1016/j.jpor.2008.08.006

Google Scholar

[7] Isaksson, H., C.C. van Donkelaar, and K. Ito, Sensitivity of tissue differentiation and bone healing predictions to tissue properties. Journal of Biomechanics, 2009. 42(5): pp.555-564.

DOI: 10.1016/j.jbiomech.2009.01.001

Google Scholar

[8] Carr, M.E. and S.L. Carr, Fibrin Structure and Concentration Alter Clot Elastic-Modulus but Do Not Alter Platelet-Mediated Force Development. Blood Coagulation & Fibrinolysis, 1995. 6(1): pp.79-86.

DOI: 10.1097/00001721-199502000-00013

Google Scholar

[9] Lin, D., et al., Dental implant induced bone remodeling and associated algorithms. Journal of the Mechanical Behavior of Biomedical Materials, 2009. 2(5): pp.410-432.

DOI: 10.1016/j.jmbbm.2008.11.007

Google Scholar

[10] Field, C., et al., Prediction of mandibular bone remodelling induced by fixed partial dentures. Journal of Biomechanics, 2010. 43(9): pp.1771-1779.

DOI: 10.1016/j.jbiomech.2010.02.016

Google Scholar

[11] Saito, M., et al., Stress distribution of abutments and base displacement with precision attachment- and telescopic crown-retained removable partial dentures. J Oral Rehabil, 2003. 30(5): pp.482-7.

DOI: 10.1046/j.1365-2842.2003.01092.x

Google Scholar

[12] Kawasaki, T., et al., Relationship between the stress distribution and the shape of the alveolar residual ridge-three-dimensional behaviour of a lower complete denture. J Oral Rehabil, 2001. 28(10): pp.950-7.

DOI: 10.1046/j.1365-2842.2001.00771.x

Google Scholar

[13] Mizuuchi, W., et al., The effects of loading locations and direct retainers on the movements of the abutment tooth and denture base of removable partial dentures. J Med Dent Sci, 2002. 49(1): pp.11-8.

Google Scholar