A Study on the Cool Charge Characteristics of Ice Storage Plate Filled with Eutectic Salt

Article Preview

Abstract:

The electricity load imbalance between day and night of air conditioning greatly affect the power generation cost and safe operation of power grid. Because of the important role in balance the peak and night electricity load, the Cool storage technology more and more attention at home and abroad. A cool storage experimental apparatus with internal melt ice-on-coil was set up, and on which the heat-transfer characteristics have been determined. The experimental results show that:The inlet temperature of refrigerant,when entering the ice storage tank, has an larger influence on the process of cool storage than the flow amount of the cooling medium. It is found by analyzing the process of experiment about storage that the suitable outlet temperature of the cooling medium is 1°C while the flow amount of the cooling medium is 0.274 m3/h. The research results can provide help for the energy-saving design of air conditioning.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

88-93

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yan Wang, Zhonghua Tang, Junjie Jin. Application and development of ice-storage technology in air-conditioning systems[J]. Energy Conservation, 2013 (5) 41-42.

Google Scholar

[2] Jiang Aihua, Huang Zhuqing. Ice storage air condition and power grid peak shaving[J]. Refrigeration, 2002 21 (1) 41-43.

Google Scholar

[3] Xintong Liu. Design and application of ice-storage air-conditioning[J]. Building Energy, 2012 40 (9 ) 9-12.

Google Scholar

[4] Jianbo Lu. The advantage and disadvantage of ice storage air condition[J]. Construction Safety, 2013 (13) 39-41.

Google Scholar

[5] Xiaolin Wang, Xiaoqiang Zhai. Review on phase change cool storage in air-conditioning system[J]. Building Science, 2013 29 (6) 98-105.

Google Scholar

[6] G.P. Henze, M. Krarti, M.J. Brandemuehl. Guidelines for improved performance of ice storage systems[J]. Energy and Buildings, 2003 (35) 111-127.

DOI: 10.1016/s0378-7788(01)00140-2

Google Scholar

[7] Guiyin Fang , Shuangmao Wu, Xu Liu. Experimental study on cool storage air-conditioning system with spherical capsules packed bed[J]. Energy and Buildings, 2010 (42) 1056–1062.

DOI: 10.1016/j.enbuild.2010.01.018

Google Scholar

[8] Yuyan Deng, Lixing Ding, Peng Xiao. Economic analysis of process cold source with the eutectic salt low temperature dynamic cool storage system[J]. HV&AC, 2010 40 (6 ) 49-52.

Google Scholar

[9] S.M. Vakilaltojjar,W. Saman. Analysis and modeling of a phase change storage system for air conditioning applications[J]. Applied Thermal Engineering 2001 (21) 249~263.

DOI: 10.1016/s1359-4311(00)00037-5

Google Scholar

[10] S. Wu, G. Fang, X. Liu, Thermal performance simulations of a packed bed cool thermal energy storage system using n-tetradecane as phase change material[J]. International Journal of Thermal Sciences, 2010 (49) 1752-1762.

DOI: 10.1016/j.ijthermalsci.2010.03.014

Google Scholar