Research of the Measurement Technique for the DC Motor Sensorless Control
Abstract:
Back-EMF zero-crossing detection can detect motor rotor position. The motor start-up problem of sensorless detection technique motor is researched. A novel three-stage start-up method is proposed to solve the problem. And it can ensure Security and reliability of motor start-up and controllability of motor rotation. There is actual theoretical basis for implementing measurement control system for the DC motor sensorless control.