Based on S-Transformation Single-Phase Transient Faults and Permanent Fault Identification

Article Preview

Abstract:

For both ends of the reactor with a parallel transmission lines, a method using Fault-phase voltage of low frequency component to Discrimine of the fault nature in Recovery voltage phase. In this method, different frequency bands is obtained by S-transform for Recovery phase of the faulted phase voltage capacity ,compare the low frequency part , in advance , determining the nature of the fault. Through theoretical analysis and a large number of verification of PSCAD, This method can effectively distinguish the fault type.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 433-440)

Pages:

6250-6255

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yaozhong Ge. New Types of Protective Relaying and Fault Location Theory and Trchniques"[M], Xi'an: Xi, an Jiaotong University Press, (1966).

Google Scholar

[2] Botong Li. The new theory of single-phase adaptive reclosure, [D]. Tianjin, Tianjin University, (2007).

Google Scholar

[3] Bin Li, Yingli Li, Kun Sheng and Zhian Zeng. EHV with shunt reactors single-phase adaptive reclose, [J]. Proceedings of the CSEE, 2004, 24(5): 52-56.

Google Scholar

[4] Junling Liu, Haofang Liu. Reaserch on phase criterion for single pole adaptive reclosure of EHV transmission lines, [J]. ANHUIELECTRIC POWER, 2006, 23(4): 47-50.

DOI: 10.1049/cp:20061785

Google Scholar

[5] Yue Fan, Wei Shi. Automatic reclosing modified criterion of voltage phase in the tranmission line, [J]. Auto of Electric Power Systems, 2004, 24(6): 44-47.

Google Scholar

[6] Haofang Liu, Zengping Wang, Yan Xu and Jing Ma. "Criterion for Determining Fault Nature in Adaptive Single-Phase Reclosing for Shunt Compensated EHV/UHV Transmission Lines; [J]. Power System Technology, 2006, 30(18): 29-34.

DOI: 10.1109/pes.2006.1709611

Google Scholar

[7] Jiale Suonan, Dandan Sun etc. Identification of permanent Faults for Single-phase Auto-reclosure on Transmission Lines with Shunt Reactors, [J]. Proceedings of the CSEE, 2006, 26(11): 75-81.

Google Scholar

[8] Hongzhi Li. Identification of transient faults for single-phase transmission line, [J]. RELAY, 2007, 35(suppl): 102-106.

Google Scholar

[9] Zengping Wang, Haofang Liu, Yan Xu and Junling Liu. A New Criterion for Single-phase Adaptive Automatic Reclosure based on improved Correlation Algorithm, [J]. Proceedings of the CSEE, 2007, 27(10): 49-54.

DOI: 10.1049/cp:20061785

Google Scholar

[10] SUI Xiao-yu, ZHAO Hong. Study on identification of permanent fault for transmission lines with shunt reactors, [J]. Power System Protection and Control, 2008, 36(18): 43-46.

Google Scholar

[11] Zhenfeng Liang, Jiale Suonan etc. Discrimination of permanent Faults for Three phase Autoreclosing Based on Model Identification, [J]. Automation of Electric Power systems, 2010, 34(8): 81-85.

Google Scholar