Improvement of the Hydrophilicity of Cu/LDPE Composite and its Influence on the Release of Cupric Ions

Article Preview

Abstract:

t is of great importance to improve the hydrophilicity of Cu/LDPE composite, a material for a new type of IUDs (Intrauterine Devices). The aim of the study is not only satisfying the biocompatibility of medical devices implanted in human bodies, but also improving the releasing rate of cupric ions. In this study, various hydrophilic materials (sodium chloride, anhydrous glucose and soluble starch) were added respectively, in order to improve the hydrophilicity of Cu/LDPE composite. The microstructure of Cu/LDPE composite was characterized, moreover, the influence of the addition of these hydrophilic materials on the surface hydrophilicity and the releasing rate of cupric ions of Cu/LDPE composite was studied. The compatibility between three hydrophilic materials and the matrix of LDPE is rather different, which can affect the dispersible uniformity of these additives in Cu/LDPE composite, and the dispersible uniformity of NaCl is the worst among these three hydrophilic materials. The addition of three hydrophilic materials was all beneficial to the improvement of the hydrophilicity of Cu/LDPE composite. Connected holes were formed in Cu/LDPE composite, which provided channels for the infiltration of solution and the diffusion of cupric ions, and improved the releasing rate of cupric ions in the Cu/LDPE composite IUDs.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volumes 745-746)

Pages:

46-52

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] C. d'Arcangues, Worldwide use of intrauterine devices for contraception, Contraception. 75 (2007) S2-S7.

DOI: 10.1016/j.contraception.2006.12.024

Google Scholar

[2] C.A. Grillo, M.A. Reigosa, M.A. Fernández, Does over-exposure to copper ions released from metallic copper induce cytotoxic and genotoxic effects on mammalian cells, Contraception. 81 (2010) 343-349.

DOI: 10.1016/j.contraception.2009.12.003

Google Scholar

[3] S.Z. Cai, X.P. Xia, C.S. Xie, Corrosion behavior of copper/LDPE nanocomposites in simulated uterine solution, Biomaterials. 26 (2005) 2671-2676.

DOI: 10.1016/j.biomaterials.2004.08.003

Google Scholar

[4] X.P. Xia, C.S. Xie, S.Z. Cai, et al., Effect of the loading and size of copper particles on the mechanical properties of novel Cu/LDPE composites for use in intrauterine devices, Mater Sci Eng A-Struct. 429 (2006) 329-333.

DOI: 10.1016/j.msea.2006.05.045

Google Scholar

[5] S.Z. Cai, Corrosion behavior and controlled release of cupric ion of copper/LDPE nanocomposites in the simulated uterine solution [Doctoral dissertation], Huazhong University of Science and Technology, (2005).

Google Scholar

[6] M. Tanaka, A. Mochizuki, N. Ishii, et al., Study of blood compatibility with poly (2-methoxyethyl acrylate). Relationship between water structure and platelet compatibility in poly (2-methoxyethylacrylate-co-2-hydroxyethylmethacrylate), Biomacromolecules. 3 (2002).

DOI: 10.1021/bm010072y

Google Scholar

[7] J.F. Ou, J.F. Zhou, L.Q. Jian, et al., Review of surface modification methods of polymer, Plastic Industry. 35 (2007) 5-10.

Google Scholar

[8] G. Tsanadis, S.N. Kalantaridou, A. Kaponis, et al., Bacteriological cultures of removed intrauterine devices and pelvic inflammatory disease, Contraception. 65 (2002) 339-342.

DOI: 10.1016/s0010-7824(02)00284-6

Google Scholar