Sort by:
Publication Type:
Open access:
Publication Date:
Periodicals:
Search results
Online since: April 2015
Authors: Amadou Adamou, Olisaemeka Osadebe
Once all data required are keyed in by the user and the “ANALYZE PLATE” tab appearing at the bottom of the GUI clicked on, the software performs the following operations in the sequence shown:
1.
Performs Gauss-Jordan reduction on the augmented matrix. 10.
Performs Gauss-Jordan reduction on the augmented matrix. 10.
Online since: July 2023
Authors: Taoheed Olohunde Sadiq, Jamaliah Idris, Nor Akmal Fadil, Izman Sudin, Ahmed Alsakkaf
These alloys possessed distinguishable biomedical features; slow degradation during the implantation without causing harmful effects and preventing the need for a further surgical operation to remove the implant, hence accelerating the healing process, leading to a reduction in cost implication, scarring, and risk [7].
Based on the approximate linear polarization data, polarization resistance (Rp) values were calculated by the Stern–Geary equation according to ASTM G59-97.
Based on the approximate linear polarization data, polarization resistance (Rp) values were calculated by the Stern–Geary equation according to ASTM G59-97.
Online since: March 2020
Authors: Jose Isagani B. Janairo, Virgilio C. Linis, Maria Rejane J. Nepacina
It is comparable to the stress-strain curve of a ductile polymer in which there was a significant reduction of steepness of stress compared to a brittle polymer which is steeper in curve [47].
[49] Cambridge University Engineering Department, in: Materials Data Book, Cambridge, Granta Design Limited (2003)
[49] Cambridge University Engineering Department, in: Materials Data Book, Cambridge, Granta Design Limited (2003)
Online since: July 2014
Authors: Mayank Jain, Lars Bøtter-Jensen
Sample-to-PM tube distance is thus very important; only a small increase will lead to a significant loss of light collected because of reduction in the collection (solid) angle.
In order to gain insight into both traps and recombination centres, it is important to obtain 3-D data in which the intensity is displayed as a function of both temperature/time/excitation-wavelength and the emission wavelength.
In order to gain insight into both traps and recombination centres, it is important to obtain 3-D data in which the intensity is displayed as a function of both temperature/time/excitation-wavelength and the emission wavelength.
Online since: January 2023
Authors: Nugraheni Puspita Rini, Edi Suharyadi, Nurul Imani Istiqomah
According to Tauc's plot, the absorbance data was also used to calculate the value of Eg.
The reaction mechanism discussed above is outlined below; CoO/ZnO + hv (UV) → CoO(eCB- + hVB+)/ZnO(eCB- + hVB+) (4) hVB+ + H2O → H+ + OH- (5) hVB+ + OH- → ∙OH (oxidation) (6) eCB- + H2O + H+ → H2O2 + O2 (7) eCB- + O2 → ∙O2- (reduction) (8) H2O2 + ∙O2- → ∙OH + OH-+ O2 (9) ∙O2- + ∙OH + MB → simple organic molecules (10) The junction between CoO and ZnO may inhibit electron–hole recombination, which can lengthen the photodegradation reaction between the free electrons and MB molecules.
The reaction mechanism discussed above is outlined below; CoO/ZnO + hv (UV) → CoO(eCB- + hVB+)/ZnO(eCB- + hVB+) (4) hVB+ + H2O → H+ + OH- (5) hVB+ + OH- → ∙OH (oxidation) (6) eCB- + H2O + H+ → H2O2 + O2 (7) eCB- + O2 → ∙O2- (reduction) (8) H2O2 + ∙O2- → ∙OH + OH-+ O2 (9) ∙O2- + ∙OH + MB → simple organic molecules (10) The junction between CoO and ZnO may inhibit electron–hole recombination, which can lengthen the photodegradation reaction between the free electrons and MB molecules.
Online since: May 2012
Authors: Hong Yan Liu, Fang Liu
Results and Discussion
3.1 Changes in vegetation
Site investigating data are presented in table 1.
The possible reason for the reduction was that the two terrains were always located in hillsides, where water was drained off easily, and caused the base cations in soil to be leached heavily; subsequently exchange cations such as Ca and Mg were lost dramatically.
The possible reason for the reduction was that the two terrains were always located in hillsides, where water was drained off easily, and caused the base cations in soil to be leached heavily; subsequently exchange cations such as Ca and Mg were lost dramatically.
Online since: December 2013
Authors: Xiao Lin Zhang, Yuan Xin Ge, Zhong Hui Li, Kang Sun
The adsorption data of Cu(II) and Pb(II) was very much in line with Langmuir isotherm.
The modified electrode showed electrocatalytic activity towards reduction of H2O2 and could reach the 95% steady-state response within 10 s.
The modified electrode showed electrocatalytic activity towards reduction of H2O2 and could reach the 95% steady-state response within 10 s.
Online since: August 2021
Authors: Galbadrakh Ragchaa, Munkhtsetseg Sambuu, Erdene-Ochir Ganbold, Enkhtor Sukhbaatar, Khandmaa Tsagaanaa, Anna Nikolaevna Oleshkevich, Natalia Mikhailovna Lapchuk
Analytical data is provided by FTIR spectroscopy measurement.
reduction of bands integrated area between 1600 − 1300 cm−1, the coal spectrum is wholly recovered by the used sample preparation.
reduction of bands integrated area between 1600 − 1300 cm−1, the coal spectrum is wholly recovered by the used sample preparation.
Online since: October 2011
Authors: Kang Hai Tan, Bo Yang
Nevertheless, since there are only very limited test data for progressive collapse loading conditions, most of the acceptance criteria and modelling parameters in DoD [1] have not been updated.
Since the heat affected zone (HAZ) near the welds can significantly alter local material properties resulting in a local reduction in ductility, the HAZ effect is considered by locally reducing the damage initiation strain and damage evolution process.
Since the heat affected zone (HAZ) near the welds can significantly alter local material properties resulting in a local reduction in ductility, the HAZ effect is considered by locally reducing the damage initiation strain and damage evolution process.
Online since: March 2008
Authors: S.K. Bhaumik, C.N. Saikrishna, K.V. Ramaiah, M.A. Venkataswamy
The RD and RS of the specimen were monitored using a non-contact
laser device of resolution 0.05 mm attached to a PC for continuous data logging.
A considerable reduction in the transformation width (hysteresis) was observed in the untrained actuator during the initial cycles, after which it remained more or less constant.
A considerable reduction in the transformation width (hysteresis) was observed in the untrained actuator during the initial cycles, after which it remained more or less constant.