Failure Analysis of Q345 Steel Structures on Port Cranes

Article Preview

Abstract:

Based on a system of macro & micro fracture appearance observation, energy spectrum analysis and metallurgical structure inspection, the cause of sample crack of Q345 steel were obtained. The results showed that the specimen occurred fatigue crack under alternating load, the crack source was a line source, the middle area of the fracture was the relatively flat topography and relatively narrow fatigue striations, the rear area of the fracture was the relatively uneven topography and relatively large fatigue striations, and a certain yield occurred at the crack tip.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

844-847

Citation:

Online since:

September 2013

Keywords:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Hongwei Wang, Research on deformation and the crack growth of steel by acoustic emission monitoring. Beihang University, China, (2010).

Google Scholar

[2] GB/T 6398-2000, Test methods of metal material fatigue crack growth rate [S]. State Quality Supervision Bureau, (2000).

Google Scholar

[3] Derek Hull. Fractography observing, measuring, and interpreting fracture surface topography [M]. Science Press. (2009).

Google Scholar

[4] Dong Zhang, Peidao Zhong, Chunhu Tao, et al. Failure analysis [M]. National Defence Industry Press, (2004).

Google Scholar

[5] Jian Chen, Wen Yan, Chunxia Liu. Materials research methods [M]. Chemical Industry Press, (2011).

Google Scholar

[6] Yixiang Hu. The practical Techniques of Metallographic Examination [M]. Machinery Industry Press, (2012).

Google Scholar