Electrochemistry Behavior of Ag/TiO2 Nanobelts and its Potential Applications on Mercapto Proteins Detection

Article Preview

Abstract:

Glassy carbon electrodes (GCEs) were modified by TiO2 and Ag/TiO2 heterostructured nanobelts, respectively. The corresponding electrodes were marked as TiO2/GCE and Ag/TiO2/GCE, respectively. The electrochemical properties of Ag/TiO2/GCE had good and stable electrochemical characteristics in phosphate buffer solution (PBS), and it can be applied to the trace detection of L-cysteine. When the concentration of L-cysteine is in 10-7 order of magnitude, it is more sensitive.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

85-91

Citation:

Online since:

December 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Y. Pan, G. A. Sonn, M. L.Y. Sin, K. E. Mach, M. C. Shih, V. Gau, P. K. Wong and J. C. Liao,Biosensors and Bioelectronics,Vol. 26(2010) , No. 2, p.649.

DOI: 10.1016/j.bios.2010.07.002

Google Scholar

[2] G. Garai-Ibabe, R. Grinyte, E. I. Golub, A. Canaan, M.L. Chapelle, R.S. Marks and V. Pavlov: Biosensors and Bioelectronics, Vol. 30, (2011), No. 1, p.272.

DOI: 10.1016/j.bios.2011.09.025

Google Scholar

[3] M.P.A. Ebert, J. Meuer, J.C. Wiemer, H.U. Schulz, M.A. Reymond, U. Traugott, P. Malfertheiner and C. Rocken: J. Proteome Res., Vol. 3(2004), No. 6, p.1261.

DOI: 10.1021/pr049865s

Google Scholar

[4] C. Melle, G. Ernst, B. Schimmel, A. Bleul and R. Kaufmann: J. Proteome Res., Vol. 4(2005), No. 5, p.1799.

Google Scholar

[5] D. Vilela, M. C. González and A. Escarpa: Analytica Chimica Acta, Vol. 751 (2012), No. 2, p.4.

Google Scholar

[6] Rajesh, V. Sharma, V.K. Tanwar, S.K. Mishra and A.M. Biradar: Thin Solid Films, Vol. 519(2010), No. 3, p.1167.

DOI: 10.1016/j.tsf.2010.08.063

Google Scholar

[7] X.Y. Zhang, L. Y. Zhou, H. Q. Luo, , N. B. Li: Analytica Chimica Acta, Vol. 776 (2013), p.11.

Google Scholar

[8] Rajesh, V. Sharma, S. K. Mishra and A. M. Biradar: Materials Chemistry and Physics, Vol. 132(2012), No. 1, p.22.

Google Scholar

[9] L.Y. Chen, Z.J. Qi, R.J. Chen, Y. Li, S.Q. Liu: Clinica Chimica Acta, Vol. 411(2010), No. 23, p. (1969).

Google Scholar

[10] Y.M. Wang, G.J. Du, H. Liu, D. Liu, S.B. Qin, N. Wang, C.G. Hu, X.T. Tao, J. Jiao, J.Y. Wang and Z.L. Wang: Advanced Functional Materials,Vol. 18(2008), p.1131.

DOI: 10.1002/adfm.200701120

Google Scholar

[11] Y.M. Wang, G.J. Du, H. Liu, D. Liu, S.B. Qin, X.T. Tao M.H. Jiang, J.Y. Wang and Z.L. Wang: Journal of Nanoscience and Nanotechnology, Vol. 9(2009), p.2119.

Google Scholar

[12] Y.M. Wang, G.J. Du, L.B. Zhu, H. Liu, C.P. Wong and J.Y. Wang: Sensors and Actuators B Vol. 174 (2012), p.570.

Google Scholar

[13] J. B. Pendry, L. Martín-Moreno and F. J. Garcia-Vidal: Science, Vol. 305(2004), No. 5685, p.847.

Google Scholar

[14] B. H. Guo, S. P. Li, L.S. Song, M. Yang, W. F. Zhou, D. Tyagi and J. S. Zhu: Applied Surface Science, Vol. 345(2015), p.379.

Google Scholar

[15] C. E. P. Maljaars, A. C. d. Souza, K.M. Halkes, P. J. Upton, S. M. Reeman, S. André, H. J. Gabius, M. B. McDonnell and J. P. Kamerling: Biosensors and Bioelectronics, Vol. 24 (2008), No. 1, p.60.

DOI: 10.1016/j.bios.2008.03.014

Google Scholar