Selective 4H-SiC UV Detectors

Article Preview

Abstract:

Carcinogenic (bactericidal) radiation (λ = 200–300 nm with a peak at 254 nm) is present in natural (Sun) and artificial (lamps) source of UV radiation. Its intensity is very low as compared to other types of radiation, but it strongly affects the health of human beings. To prevent oncological diseases, it is important to monitor the carcinogenic radiation level; i.e., selective photodetectors are required. A UV photodetectors based on n-4H-SiC Schottly barriers and p+-n junctions are proposed. The quantum efficiency spectrum of such detectors is very close to the spectrum of relative action of carcinogenic radiation on human beings due to the direct optical transition at 4.9 eV in 4H-SiC. The quantum efficiency (at the spectral peak 254 nm) amounts to about 0.3 electrons/photon for virtually zero sensitivity in other spectral regions. Quantum efficiency in the wavelength range 247–254 nm is practically independent of temperature in the range from −100 to +300°C.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volumes 740-742)

Pages:

1014-1017

Citation:

Online since:

January 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] L.R. Koller, Ultraviolet Radiation, N.Y.: Willey, (1965).

Google Scholar

[2] G.F. Kholuyanov, On the mechanism of Charge Carrier Collection in Silicon Carbide Diffusion-Photodetectors, Sov. Physics and Technics of Semiconductors 3 (1969) 658-664.

Google Scholar

[3] R.G. Verenchikova, Yu.A. Vodakov, D.P. Litvin, E.N. Mokhov, A.D. Roenkov, V.I. Sankin, Ultraviolet Silicon Carbide Photodetectors, Semiconductors 26 (1992) 1008-1013.

Google Scholar

[4] D.M. Brown, E.T. Downey, M. Ghezzo, J.W. Kretchmer, R.J. Saia, Y.S. Liu, J.A. Edmond, G. Gati, J.M. Pimbley, W. E. Schneider, Silicon Carbide UV Photodiodes, IEEE Trans. on Electron Devices 40 (1993) 327-331.

DOI: 10.1109/16.182509

Google Scholar

[5] Y. Feng, X. Xiaobin, S. Aslam, Z. Yuegang, D. Franz, J.H. Zhao, M. Weiner, 4H-SiC UV photo detectors with large area and very high specific detectivity, IEEE J. Guantum Electronics 40 (2004) 1315-1320.

DOI: 10.1109/jqe.2004.833196

Google Scholar

[6] T.V. Blank, Y.A. Gol`dberg, Semiconductor Photoelectric Converters for the Ultraviolet Region of the Spectrum, Semiconductors 37 (2003) 999-1030.

DOI: 10.1134/1.1610111

Google Scholar

[7] T.V. Blank, Y.A. Gol`dberg, E.V. Kalinina, O.V. Konstantinov, 4H-SiC-Based Photodetector of Carcinogenic UV Radiation, Technical Physics 78 (2008) 81-84.

DOI: 10.1134/s1063784208010155

Google Scholar

[8] T.V. Blank, Y.A. Gol`dberg, E.V. Kalinina, A.N. Karpenko, An Instrument for Measuring the Intensity and Dose of Cancerigenic Ultraviolet Radiation, Instruments and Experimental Techniques 53 (2010) 743-745.

DOI: 10.1134/s0020441210050234

Google Scholar