Residual Stresses in Cast Ni-Cr Alloys-Ceramics Joints with an Intermediate Layer

Article Preview

Abstract:

The results of residual stresses in biocompatible cast Ni-Cr alloys-ceramics joints with an intermediate layer with thickness of about 10μm are discussed. To the experiment were used specimens with dimensions of 45×3×10 mm and 45×4×10 mm made of Cr-Ni alloys-ceramics joint both with and without of application of an intermediate layer. The examinations were carried out by means of metallographical microscope, testing machine and X-ray diffractometer. The measurement of residual macrostresses was carried out by using sin2ψ method. The obtained experimentally values of residual macrostresses are in good agreement with results of numerical simulation performed by means of FEM ANSYS package. The researches have been shown that application of an intermediate ceramics layer influence on increase of strength properties of Ni-Cr alloys-ceramics joints.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1551-1557

Citation:

Online since:

October 2006

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2006 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] M. Nałęcz.: Biomateriały. Biocybernetyka i inżynieria biomedyczna 2000". Warszawa. Wyd. "PWN, Vol. 4 (2003).

Google Scholar

[2] R. Adell, U. Lekholm, B. Rockler, PI. Branemark: A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981 10 (6): 387-416.

DOI: 10.1016/s0300-9785(81)80077-4

Google Scholar

[3] K. Anusavice, JE. Carroll :. Effect of incompatibility stress on the fit of metal ceramic crowns. J Dent Res 1987; 66 (8): 1341-5.

DOI: 10.1177/00220345870660081101

Google Scholar

[4] DV. Bridger, J.I. Nicholls: Distortion of ceramometal fixed partial dentures during the firing cycle. J Prosthet Dent 1981; 45: 507-14.

DOI: 10.1016/0022-3913(81)90036-6

Google Scholar

[5] R.A. Bryant , J.T. Nicholls: Measurement of distortions in fixed dentures resulting from degassing. J Prosthet Dent 1979; 42: 515-20.

DOI: 10.1016/0022-3913(79)90244-0

Google Scholar

[6] R.L. Burguete, R.B. Johns, T. King, E.A. Patterson: Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994; 71: 592-9.

DOI: 10.1016/0022-3913(94)90443-x

Google Scholar

[7] N. Ray.: Dental materials. Lecture Notes. Handbook. /www. freebooks4doctors. com/ (2001). Dentistry in 21 st. Century Supplement. /www. ada. org: JADA dentistry in 21 st. Century. Supplement.

Google Scholar

[8] Y. Jung, P. Papadopoulos, R.O. Ritche: Constitutive modeling and numerical simulation of multivariant phase transformation in superelastic alloys. Int. J. Num. Meth. Engin, (2002) submitted.

DOI: 10.1002/nme.940

Google Scholar

[9] J. Juraszek: Analysis of end-face seals by FEM. Acta Montanistica No. 3, (2002) p.199.

Google Scholar

[10] J. Juraszek: Data Base of Material Parameters for Analysis Forming Process by FEM. International Metallurgical Symposium, Metal 2002, Ostrava, Czech Republic, Vol 2. (2002), p.127.

Google Scholar

[11] J. Juraszek, J. Nowak: Analysis of Shapes Jaw in Clasping Process. International Metallurgical Symposium, Metal 2000, Ostrava, Czech Republic Vol. 1 (2000) p.48.

Google Scholar

[12] J. Juraszek: Analysis of the Clasp Joint. GAMM TU Leipzig, (1992).

Google Scholar

[13] J. Juraszek: Analysis of the Multiple Clasp-Joint. GAMM TU Dresden (1993) p.112.

Google Scholar

[14] J. Juraszek: Analysis of the Hexagonal Clasp-Joint - plastizitat. GAMM TU Braunschweig, (1994), p.78.

Google Scholar

[15] J. Juraszek: Elasto-Plastic Analysis of the Clasping Process. Gesellschaft fur Angewandte Mathematik und Mechanik, GAMM'99, Metz (1999).

Google Scholar

[16] J. Juraszek: Elasto-Plastic Analysis of the Wire. TU Regensburg. GAMM (1997), p.7.

Google Scholar

[17] J. Juraszek: Simulation of plastic deformation of hexagonal clasp by FEM. International Metallurgical Symposium Metal'97, Vol. 4, 1997, Ostrava, Czech Republic (1997), p.97.

Google Scholar

[18] J. Juraszek: Strength analysis of a multi-clip joint. Journal of Theoretical and Applied Mechanics Vol. 4, (2005), p.893.

Google Scholar

[19] J. Juraszek: The clamped joints - a survey and analysis of shapes and materials. Journal of Theoretical and Applied Mechanics Vol. 1, (2006), p.51.

Google Scholar

[20] A.P. Karafillis and M.C. Boyce: Tooling design in sheet metal forming using springback calculations. Int. J. Mech. Sci. Vol. 34, (1992), p.113.

DOI: 10.1016/0020-7403(92)90077-t

Google Scholar

[21] M. Kleiber, H. Antunez., T. Hien, P. Kowalczyk: Parameter sensivity in Nonlinear Mechanics. J. Wiley (1997).

Google Scholar

[22] M. Kleiber: Metoda elementów skończonych w nieliniowej mechanice kontinuum. PWN, Warszawa (1984).

Google Scholar