Using Intrinsic Defect Spectra in 4H SiC as Imbedded Thermometers in the Temperature Range from 100°C to 1500°C

Abstract:

Article Preview

Low doped epitaxial films of 4H SiC irradiated at 1 MeV and electron fluences of 1×1015 cm-2, 3×1015 cm-2 and 1×1016 cm-2 have been used to measure temperatures in two temperature intervals: 580°C to 640°C and 1220°C to 1320°C. Possible accuracy of the temperature measurements is judged to be better than 10 degrees Centigrade. Similar measurements should be possible from 100°C to 1500°C.

Info:

Periodical:

Materials Science Forum (Volumes 679-680)

Edited by:

Edouard V. Monakhov, Tamás Hornos and Bengt. G. Svensson

Pages:

237-240

DOI:

10.4028/www.scientific.net/MSF.679-680.237

Citation:

F. Yan et al., "Using Intrinsic Defect Spectra in 4H SiC as Imbedded Thermometers in the Temperature Range from 100°C to 1500°C", Materials Science Forum, Vols. 679-680, pp. 237-240, 2011